@beerwright/core
    Preparing search index...

    Interface StandModelOptions

    interface StandModelOptions {
        ambientTempC: number;
        coolingRateConstantPerMin: number;
        endTempC?: number;
        integrationStepMinutes: number;
        standMinutes: number;
        startTempC: number;
    }
    Index
    ambientTempC: number

    Ambient temperature the wort decays towards, °C.

    coolingRateConstantPerMin: number

    Cooling rate constant k, per minute. Ignored when endTempC is usable.

    endTempC?: number

    Wort temperature at the end of the stand, °C, if the brewer knows it.

    If it's set, k is solved so the curve ends there, and coolingRateConstantPerMin is ignored: k = ln((T₀ − T_a) / (T_end − T_a)) / t. An end equal to the start gives k = 0, which is the fixed-temperature integral. An end above the start, or at or below ambient, isn't a cooling curve, so the stand is treated as held at the start temperature.

    integrationStepMinutes: number

    Integration step, minutes.

    standMinutes: number

    Stand duration, minutes.

    startTempC: number

    Wort temperature at the start of the stand, °C.