@beerwright/core
    Preparing search index...

    Function co2VolumesFromPressure

    • Volumes of CO₂ dissolved at a given temperature and gauge pressure.

      V = (P + 14.695) × (0.01821 + 0.09011 × e^(−(T − 32) / 43.11)) − 0.003342
      

      with P in PSI gauge and T in °F. This is the empirical fit of the standard carbonation tables that keg calculators use. Inputs are °C and PSI and converted internally. We keep PSI because regulators are labelled in it.

      Parameters

      • tempC: number
      • pressurePsi: number

      Returns number