Volumes of CO₂ dissolved at a given temperature and gauge pressure.
V = (P + 14.695) × (0.01821 + 0.09011 × e^(−(T − 32) / 43.11)) − 0.003342 Copy
V = (P + 14.695) × (0.01821 + 0.09011 × e^(−(T − 32) / 43.11)) − 0.003342
with P in PSI gauge and T in °F. This is the empirical fit of the standard carbonation tables that keg calculators use. Inputs are °C and PSI and converted internally. We keep PSI because regulators are labelled in it.
P
T
Volumes of CO₂ dissolved at a given temperature and gauge pressure.
with
Pin PSI gauge andTin °F. This is the empirical fit of the standard carbonation tables that keg calculators use. Inputs are °C and PSI and converted internally. We keep PSI because regulators are labelled in it.